A combination unit like the KF1801Vi puts both compartments in one cabinet but keeps their cooling separate, which is exactly why a fridge that has gone warm while the freezer stays frozen is a perfectly coherent sign rather than a contradiction. Owners often call describing it as impossible. It is not – it simply localises the problem to one circuit and rules out a great deal of the appliance.
Key Features
- 30" fully-integrated fridge-freezer combination
- Separate cooling circuits for the two compartments
- Dynamic cooling in the refrigerator section
- Icemaker with a dedicated water connection
Most Common Issues on This Model
One compartment failing while the other continues to work
Defrost drain blockage in the refrigerator section
Door gasket wear on the taller refrigerator door