Where the T7634 differs from a typical vented dryer is the amount of lint it will tolerate before complaining, which sounds like a virtue and is not: by the time performance drops noticeably, the blower housing can be substantially packed. We open these up regularly and find a decade of accumulated lint behind an apparently clean filter. Annual internal cleaning is a genuine safety measure on this model, not an upsell.
Key Features
- Vented Novotronic dryer with a honeycomb drum
- Electronic program control with residual moisture sensing
- Anti-crease phase after the cycle ends
- Lint filter in the door aperture
Most Common Issues on This Model
Lint bypassing a poorly-seated filter and packing the blower housing
Drum bearing at the rear of the cabinet drying out and squealing
Door catch losing its grip so the drum stops mid-cycle