The T1520 is a vented Novotronic dryer, and on a machine of this age the thermal cut-out is doing more work than the designers intended – not because the dryer has degraded but because twenty-year-old vent ducting is rarely as clear as it was on day one. Before anything inside the cabinet is condemned on this model, the duct run needs checking end to end. Restricted airflow is both the most common problem and the one with a genuine fire risk attached.
Key Features
- Vented Novotronic dryer with a rotary program selector
- Stainless drum with a reversing tumble action
- Two-stage lint filter in the door opening
- Timed and sensor-assisted drying programs
Most Common Issues on This Model
Drum support rollers flat-spotting and thumping on every revolution
Belt stretching and slipping, so the motor runs but the drum barely turns
Thermal cut-out tripping when the vent run is restricted