Miele Cooktop

Miele KM362

Model # KM362

The flame-failure device on a KM362 is a thermocouple heated by the flame, holding a valve open. As it ages its output falls, and the characteristic sign is a burner that lights, burns normally while you hold the knob in, and goes out a second or two after you let go. That description alone identifies the part, and it is a safety part doing exactly what it is meant to when it fails – shutting the gas off.

Key Features

  • Four-burner sealed gas cooktop
  • Rotary controls with a flame-failure safety device
  • Enamelled cast iron pan supports
  • Stainless or enamelled surface

Most Common Issues on This Model

01

Flame-failure thermocouple ageing so burners shut off after release

02

Ignition module failing to spark on one or more burners

03

Surface sealing gasket perishing and letting spills beneath the hob

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

FAQ

Miele KM362 FAQ

The flame-failure thermocouple is not generating enough signal to hold the gas valve open. It is a safety device and a routine replacement.

No. It is the device that shuts the gas off if a flame blows out, and it should never be bypassed.