A NoFrost freezer that is building ice is contradicting its own design, and on the KFN9855 iDE that is the clearest possible signal of a defrost problem. The system runs a heater periodically to clear the evaporator; if the heater, its sensor or its timing fails, ice accumulates until airflow stops and the compartment warms. Catching it while the ice is still modest keeps the job small.
Key Features
- Freestanding bottom-freezer with NoFrost
- PerfectFresh drawers with humidity control
- Electronic controls with SuperCool and SuperFrost
- Interior LED lighting
Most Common Issues on This Model
Defrost heater problems producing evaporator icing
Fan motor wear
Door alarm module failure